Schedule 80 PVC has the same outside diameter as Schedule 40 but thicker walls. For 1 inch, the minimum wall is 0.179 inch and the inside diameter is about 0.957 inch.
Last verified October 5, 2026
Quick lookup
1/8 inch PVC Schedule 40
- Minimum wall
- 0.068 in (1.73 mm)
- Inside diameter (approx.)
- 0.269 in
- Outside diameter
- 10.3 mm
Schedule 80 PVC pipe size chart, 1/8 to 12 inch
Schedule 80 walls are thicker than Schedule 40 at the same nominal size, so the outside diameter matches and the inside diameter is smaller. Inside diameter is outside diameter minus two minimum walls, so it is a close upper limit. Actual pipe runs slightly smaller where the wall is thicker than the minimum. Pressure ratings and weights are not shown because we have not confirmed them from two manufacturers.
| Nominal size | OD (in) | OD (mm) | Min wall (in) | Min wall (mm) | ID (in) | ID (mm) |
|---|---|---|---|---|---|---|
| 1/8" | 0.405 | 10.3 | 0.095 | 2.41 | 0.215 | 5.5 |
| 1/4" | 0.540 | 13.7 | 0.119 | 3.02 | 0.302 | 7.7 |
| 3/8" | 0.675 | 17.1 | 0.126 | 3.20 | 0.423 | 10.7 |
| 1/2" | 0.840 | 21.3 | 0.147 | 3.73 | 0.546 | 13.9 |
| 3/4" | 1.050 | 26.7 | 0.154 | 3.91 | 0.742 | 18.8 |
| 1" | 1.315 | 33.4 | 0.179 | 4.55 | 0.957 | 24.3 |
| 1-1/4" | 1.660 | 42.2 | 0.191 | 4.85 | 1.278 | 32.5 |
| 1-1/2" | 1.900 | 48.3 | 0.200 | 5.08 | 1.500 | 38.1 |
| 2" | 2.375 | 60.3 | 0.218 | 5.54 | 1.939 | 49.3 |
| 2-1/2" | 2.875 | 73.0 | 0.276 | 7.01 | 2.323 | 59.0 |
| 3" | 3.500 | 88.9 | 0.300 | 7.62 | 2.900 | 73.7 |
| 3-1/2" | 4.000 | 101.6 | 0.318 | 8.08 | 3.364 | 85.4 |
| 4" | 4.500 | 114.3 | 0.337 | 8.56 | 3.826 | 97.2 |
| 5" | 5.563 | 141.3 | 0.375 | 9.52 | 4.813 | 122.3 |
| 6" | 6.625 | 168.3 | 0.432 | 10.97 | 5.761 | 146.3 |
| 8" | 8.625 | 219.1 | 0.500 | 12.70 | 7.625 | 193.7 |
| 10" | 10.750 | 273.1 | 0.593 | 15.06 | 9.564 | 242.9 |
| 12" | 12.750 | 323.8 | 0.687 | 17.45 | 11.376 | 289.0 |
How to use this chart
Find the nominal size and read across for outside diameter, minimum wall and inside diameter in inches and millimeters. Thicker walls give Schedule 80 a smaller opening, so it moves less water but handles more pressure. The inside diameter is outside diameter minus two minimum walls, so it is a close upper limit.
Frequently asked questions
What is the wall thickness of 1 inch Schedule 80 PVC?
The minimum wall is 0.179 inch (4.55 mm).
Can Schedule 80 fittings be used with Schedule 40 pipe?
Yes. The outside diameters match, so fittings of either schedule fit either pipe. The joint is only as strong as its weakest part.
Why is Schedule 80 PVC darker?
Many makers color Schedule 80 gray and Schedule 40 white, so you can tell them apart. The color is a convention, not a rule.
How much smaller is the inside diameter of Schedule 80?
For 1 inch pipe it is about 0.092 inch smaller than Schedule 40.
Does Schedule 80 PVC handle hot water?
Not well. PVC loses strength with heat, and ratings drop above room temperature. Check the maker's data for your use.
Explore the whole Calcs family here.
Tell us which value looks off and we will check it against the sources. Report an issue
Tell us what you looked for. Suggest a chart
Disclaimer. Ratings depend on temperature, fittings and installation. Check the manufacturer's current data. Charts & Specs is an independent reference site. It is not affiliated with any manufacturer, standards body or code organization, and it uses brand and standard names only to identify what a value applies to.