PVC Pipe Size Chart

PVC pipe is sold by nominal size, not by measured size. For example, 1 inch PVC measures 1.315 inches outside, with an inside diameter of about 1.049 inch in Schedule 40 and 0.957 inch in Schedule 80.

Last verified October 5, 2026

Download PDF
PVC pipe lookup

Quick lookup

0.405" OD

1/8 inch PVC Schedule 40

Minimum wall
0.068 in (1.73 mm)
Inside diameter (approx.)
0.269 in
Outside diameter
10.3 mm

PVC pipe size chart, Schedule 40 and Schedule 80, 1/8 to 12 inch

Inside diameter is outside diameter minus two minimum walls, so it is a close upper limit. Actual pipe runs slightly smaller where the wall is thicker than the minimum. Pressure ratings and weights are not shown because we have not confirmed them from two manufacturers.

Nominal sizeOD (in)OD (mm)Sch 40 min wall (in)Sch 40 ID (in)Sch 80 min wall (in)Sch 80 ID (in)
1/8"0.40510.30.0680.2690.0950.215
1/4"0.54013.70.0880.3640.1190.302
3/8"0.67517.10.0910.4930.1260.423
1/2"0.84021.30.1090.6220.1470.546
3/4"1.05026.70.1130.8240.1540.742
1"1.31533.40.1331.0490.1790.957
1-1/4"1.66042.20.1401.3800.1911.278
1-1/2"1.90048.30.1451.6100.2001.500
2"2.37560.30.1542.0670.2181.939
2-1/2"2.87573.00.2032.4690.2762.323
3"3.50088.90.2163.0680.3002.900
3-1/2"4.000101.60.2263.5480.3183.364
4"4.500114.30.2374.0260.3373.826
5"5.563141.30.2585.0470.3754.813
6"6.625168.30.2806.0650.4325.761
8"8.625219.10.3227.9810.5007.625
10"10.750273.10.36510.0200.5939.564
12"12.750323.80.40611.9380.68711.376

How to use this chart

Find the nominal size, then read the outside diameter, minimum wall and inside diameter for Schedule 40 and Schedule 80. Inside diameter is outside diameter minus two minimum walls, so treat it as a close upper limit. If you do not know your pipe size, measure the outside diameter with calipers and match it to the table, or use the pipe size finder.

Frequently asked questions

What is the actual outside diameter of 1 inch PVC pipe?

1.315 inches. The nominal size is a name, not a measurement.

What is the difference between Schedule 40 and Schedule 80 PVC?

Both have the same outside diameter, so they fit the same fittings. Schedule 80 has thicker walls, so it has a smaller inside diameter and a higher pressure rating.

What is the inside diameter of 2 inch PVC pipe?

About 2.067 inches for Schedule 40 and 1.939 inches for Schedule 80, using the minimum wall.

How do I measure PVC pipe size?

Measure the outside diameter and compare it with the chart. Or wrap a string around the pipe, measure the string and divide by 3.1416.

Why does this chart not show pressure ratings?

We only publish values we have confirmed from at least two manufacturers. Ratings change with temperature and fitting, so use the maker's current data.

Disclaimer. Ratings depend on temperature, fittings and installation. Check the manufacturer's current data. Charts & Specs is an independent reference site. It is not affiliated with any manufacturer, standards body or code organization, and it uses brand and standard names only to identify what a value applies to.

Last verified October 5, 2026. How we verify explains our two-source rule and what we leave out.

Sources used on this page
  • Spears Mfg Schedule 40 PVC pipe dimensions
  • Harvel PVC Schedule 40 pipe spec
  • Spears Mfg Schedule 80 PVC pipe dimensions
  • Harvel PVC Schedule 80 pipe spec
  • Georg Fischer PVC Schedule 80 pipe specification
  • Charlotte Pipe PVC Schedule 80 pipe data sheet
  • Charlotte Pipe PVC Schedule 40 pipe data sheet